CBCSG - TECH-GARD RUST INHIBITIVE PRIMER RED OXIDE, 155

  • MSDS: CBCSG
  • Manufacturer: PRATT AND LAMBERT
  • Product Name: TECH-GARD RUST INHIBITIVE PRIMER RED OXIDE, 155
  • National Stock Number: 8010-00N065178
Product Identification

Product ID:TECH-GARD RUST INHIBITIVE PRIMER RED OXIDE, 155
MSDS Date:07/20/1993
FSC:8010
NIIN:00N065178
MSDS Number: CBCSG

Responsible Party
PRATT & LAMBERT
BUFFALO, NY 14240
US

Emergency Phone: 800-255-3924

Info Phone: 716-873-6000

Cage: 77359

Contractor
PRATT & LAMBERT
BUFFALO, NY 14240 US

Telephone: 716-873-6000

Cage: 77359

Ingredients

SILICA, CRYSTALLINE - QUARTZ; (SILICA, CRYSTALLINE)

CAS: 14808-60-7

RTECS: VV7330000

Fraction By Weight: <5%

OSHA PEL 0.1 MG/M3 (MFR)

ACGIH TLV: 0.1 MG/M3 RDUST


6.7%.

CAS: 8030-30-6

RTECS: DE3030000

Fraction By Weight: 5%

OSHA PEL 300 PPM (MFR)

ACGIH TLV: 300 PPM (MFR)


12 @ 20C.

CAS: 64742-89-8

Fraction By Weight: 10%

OSHA PEL N/K

ACGIH TLV: N/K


SOLVENT NAPHTHA (PETROLEUM) MEDIUM ALIPHATIC; (MINERAL

CAS: 64742-88-7

Fraction By Weight: 10-15%

OSHA PEL 100 PPM (MFR)

ACGIH TLV: 100 PPM (MFR)


LESS WATER & NPRS - 3.45

RTECS: 9999999VO


ABSORB. USE ONLY NON-SPARKING TOOLS. PLACE

RTECS: 9999999ZZ


CONTAMINATION OF SEWERS, STREAMS & GROUNDWATER

RTECS: 9999999ZZ


RESTRICTED VENT AREAS NIOSH/MSHA APPRVD CHEM

RTECS: 9999999ZZ


SPRAYING, MECH PREFILTER MAY ALSO BE REQD. IN

RTECS: 9999999ZZ


TLV'S LISTED ARE EXCEEDED USE PROPERLY FITTED

RTECS: 9999999ZZ


29 CFR 1910.134 "RESP PROT" & "RESP PROT A MANUAL &

RTECS: 9999999ZZ


MAY BE LISTED IN INGREDIENTS. REFER TO INDUSTRIAL

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:INGEST:CAN CAUSE GI IRRIT, NAUS &
VOMIT. ASPIR OF MATL INTO LUNG MAY CAUSE CHEM PNEUM WHICH CAN BE
FATAL. INHAL:MAY CAUSE NOSE/THROAT IRRIT. HIGH CONCS MAY CAUSE
ACUTE CNS DEPRESS CHARACT BY HDCHS, DI ZZ, NAUS & CONFUSN. EYE:MAY
CAUSE IRRIT. SKIN:MAY CAUSE DEFAT & IRRIT. RPTD & PRLNG OCCUP
OVEREXP TO (EFTS OF OVEREXP)
Explanation of Carcinogenicity:SILICA, CRYSTALLINE-QUARTZ:IARC
MONOGRAPHS, SUPP, VOL 7, PG 341, 1987:GRP 2A. NTP 7TH ANNUAL RPT ON
CARCINS, (SUPDAT)
Effects of Overexposure:HLTH HAZ:CRYSTALLINE SILICA MAY CAUSE
SILICOSIS, PROGRESSIVELY DISABLING LUNG DISEASE. REPORTS HAVE ASSOC
PRLNG & RPTD OCCUP OVEREXP TO SOLVS W/PERM BRAIN & NERV SYS DMG.
INTENTIONAL MISUSE BY DELIB C ONCENTRATING & INHALING CONTENTS MAY
BEHARMFUL/FATAL.
Medical Cond Aggravated by Exposure:PREEXISTING RESPIRATORY CONDITIONS
MAY BE AGGRAVATED BY EXPOSURE TO CRYSTALLINE SILICA.

First Aid

First Aid:INGEST:DO NOT INDUCE VOMIT. CALL POIS CTL CTR, HOSPITAL EMER
ROOM/MD IMMED. INHAL:REMOVE TO FRESH AIR IMMED. IF BRTHG HAS
STOPPED, GIVE ARTF RESP. KEEP WARM & QUIET. GET MED ATTN IMMED.
EYE:FLUSH W/LG AMTS OF WATER, LIFTING UPPER & LOWER LIDS OCCAS.
CONTINUE FOR AT LST 15 MINS. GET MED ATTN. SKIN:REMOVE CONTAM
CLTHG. WASH AFFECTED AREA W/SOAP & WATER. OBTAIN MED ATTN IF IRRIT
PERSISTS. (SUPP DATA)

Fire Fighting

Flash Point:45.0F,7.2C
Lower Limits:SEE INGS
Upper Limits:SEE INGS
Extinguishing Media:USE NFPA CLASS B FIRE EXTINGS (CARBON DIOXIDE, ALL
PURPOSE DRY CHEM/ALCOHOL FOAM) DESIGNED TO EXTING FLAMM LIQ
(SUPDAT)
Fire Fighting Procedures:USE NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP .
WATER MAY BE INEFT, BUT MAY BE USED TO COOL EXPOS CNTNRS TO PVNT
PRESS BUILD-UP & POSS AUTO-IGNIT/ (SUPDAT)
Unusual Fire/Explosion Hazard:DURING EMERGENCY CONDITIONS, OVEREXP TO
DECOMPOSITION PRODUCTS MAY CAUSE HEALTH HAZARD. SYMPS MAY NOT BE
IMMED APPARENT. OBTAIN MED ATTN. WARNING! FLAMMABLE.

Accidental Release

Spill Release Procedures:KEEP SPECTATORS AWAY. ELIM ALL IGNIT SOURCES
(FLAMES, HOT SURFS & SOURCES OF ELEC, STATIC/FRICTIONAL SPKS). DIKE
& CONTAIN SPILL W/INERT MATL (E.G. SAND, EARTH). TRANSFER LIQS TO
COVERED METAL CNTNRS FOR RECOVERY/DISP, OR REMOVE W/INERT (ING 6)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:DO NOT STORE >115F (46C), STORE LG
QTYS IN COMPLIANCE W/OSHA 29 CFR 1910.106. DO NOT TAKE INTERNALLY.
CLOSE CNTNR AFTER EACH USE.
Other Precautions:DO NOT BREATHE SANDING DUST. EMPTY CNTNRS MUST NOT BE
WASHED & RE-USED FOR ANY PURPOSE. CNTNRS SHOULD BE GROUNDED &
BONDED TO RECEIVING CNTNR. DO NOT WELD, BRAZE/CUT ON EMTPY CNTNR.
NEVER USE PRESS TO EMPTY. DRUM IS NOT A PRESSURE VESSEL.

Exposure Controls

Respiratory Protection:PROPER SELECTION OF RESP PROT DEPENDS UPON MANY
FACTORS INCL DURATION/LEVEL OF EXPOS & CNDTNS OF USE. IN GEN EXPOS
TO ORG CHEMS SUCH AS THOSE CONTAINED IN THIS PROD MAY NOT REQ USE
OF RESP PROT IF USE D IN WELL VENTILATED AREAS. IN (ING 8)
Ventilation:PROVIDE LOC EXHST VENT IN SUFFICIENT VOL & PATTERN SO AS TO
MAINTAIN EXPOS BELOW NUISANCE DUST LIMS & PELS WHICH(ING 12)
Protective Gloves:SOLVENT IMPERMEABLE GLOVES.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
ANSI DESIGN CRITERIA . OTHER PROT EQUIP NOT LIKELY TO BE NEEDED.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
EXTING MEDIA:FIRES. POLYMER FOAM IS PREF FOR LG FIRES. FIRE FIGHT
PROC:EXPLO WHEN EXPOS TO EXTREME HEAT. IF WATER IS USED, FOG NOZZ
ARE PREF. EXPLAN OF CARCIN:1994:ANTIC TO BE CARCIN. FIRST AID
PROC:N OTES TO MD:ANY TREATMENT THAT MIGHT BE REQD FOR OVEREXP
SHOULD BE DIRECTED AT CONTROL OF SYMPS & CLINICAL CNDTNS.

Chemical Properties

Boiling Pt:B.P. Text:>203F,>95C
Vapor Pres:SEE INGS
Vapor Density:HVR/AIR
Spec Gravity:1.4
Evaporation Rate & Reference:SLOWER THAN DIETHYL ETHER
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:54

Stability

Stability Indicator/Materials to Avoid:YES
STRONG ACIDS OR ALKALINE MATERIALS.
Stability Condition to Avoid:AVOID EXCESSIVE HEAT (>115F (46C)) &
SOURCES OF IGNITION.
Hazardous Decomposition Products:BURNING, INCLUDING WHEN HEATED BY
WELDING OR CUTTING, WILL PRODUCE SMOKE, CARBON MONOXIDE & CARBON
DIOXIDE.

Disposal

Waste Disposal Methods:DISPOSE I/A/W FEDERAL, STATE & LOCAL
REGULATIONS. THIS PRODUCT, IF DISCARDED DIRECTLY, WOULD BE
CLASSIFIED AS HAZ WASTE BASED ON ITS IGNITABILITY CHARACT, I.E. HAS
FLASH POINT OF 140F (60C) OR LESS. P ROPER RCRA CLASSIFICATION
WOULD BE D001.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.